The Machinery Regulation (EU) 2023/1230 applies from 20 January 2027, and part of it is about connections, software and remote access. On that date it replaces the Machinery Directive 2006/42/EC. Much of that you can record yourself in NetBox, with open tools that Packetflow publishes for free. Packetflow helps where you want it to: reviewing the model, mapping a machine’s network with you, and setting up remote access with a work permit per intervention. The risk assessment and the conformity of the machine stay with you as the manufacturer.
Below, per requirement: what the regulation asks, what you can do yourself and where Packetflow steps in. The requirements are summarised in plain words. The text of the regulation has the last word.
The tools
| Tool | What it does |
|---|---|
| NetBox | Documents devices, interfaces, IP addresses and cables |
| netbox-topology-views | Draws the cabling from NetBox, exports PNG or XML for draw.io |
| ot-devicetypes (Packetflow) | Builds NetBox device types from the GSDML files of PROFINET devices |
| netbox-ot (Packetflow) | Zones and conduits per IEC 62443, connections with protocol, port and direction, an access map as SVG, firewall rules as CSV, a firmware version field, a drawing per machine for the technical file |
| netbox-access-paths (Packetflow) | A register of every access path: method, who, multi-factor sign-in, approved by, expiry and review |
All five are open source under the Apache 2.0 licence. The ot-devicetypes data is under CC0.
1. Connections must not create a hazard
The regulation. Annex III, section 1.1.9: connecting another device to the machine, directly or through a remote device, must not lead to a hazardous situation. Annex IV asks the technical file for drawings and schemes of the machine, its components and circuits, with the explanations to understand them.
Do it yourself. Document one reference machine per type in NetBox: every device with its interfaces and addresses, and the cables between them. netbox-topology-views draws the cabling. In netbox-ot you record the zones (the machine, the customer’s network, the vendor) and every connection that crosses the machine’s boundary, with protocol, port and direction. Under OT > Machine drawing you pick the machine’s tag or location, and netbox-ot draws the devices per zone, the cables, the addresses with NAT, the firmware and the connections to the outside, with remote access marked.
Packetflow. Maps the machine’s network with you, at the machine or from your schematics, and checks that every connection to the outside is accounted for.
2. The component that gives access
The regulation. Section 1.1.9: a hardware component that transmits signals or data and gives access to software critical for conformity must be protected against corruption, and the machine collects evidence of every intervention in that component. A router in the cabinet for remote access can be such a component.
Do it yourself. Record every way into the machine in netbox-access-paths: VPN, router, vendor tool or console, who uses it, with which sign-in, who approved it and until when. The register exports as CSV or Markdown for the file, and a review queue shows which paths are due for another look.
Packetflow. Sets up permit-based remote access:
- The engineer requests access: which machine, what for, from when until when.
- The owner of the machine approves the request. Without approval nothing opens.
- The engineer signs in to one bastion, with multi-factor sign-in, and reaches only that machine.
- The session is logged and recorded.
- When the window ends, access closes on its own.
Where your machine stands at a customer with a Packetflow platform, your engineers come in through that door and no router of your own is needed in the cabinet. If you ship to customers without such a platform, Packetflow works out a reference design that you repeat on every machine of that type.
3. The software on the machine
The regulation. Section 1.1.9: software and data critical for conformity are identified as such and protected. The machine identifies the software installed on it that it needs to operate safely, at all times and in an easily accessible form.
Do it yourself. netbox-ot adds a firmware version field to devices and modules. Fill it in per device and export the list per machine type as CSV. That list is your source for the file and the instructions. The machine itself must also be able to show the information, on the HMI for example: that stays work in the controls.
Packetflow. Sets up the export so every machine of a type gets the same list, and helps decide which devices belong on it.
4. Recording interventions
The regulation. Section 1.1.9: the machine collects evidence of every legitimate or illegitimate intervention in the software or its configuration. Section 1.2.1 (f): the tracing log of interventions and of safety software versions uploaded later stays available for five years.
Do it yourself. This lives in the machine: the PLC, the HMI or the machine’s PC records what changes. The tools above document the design. They do not record interventions on the machine.
Packetflow. Sends the logs of the machine and of remote access to a place outside the machine, where they are kept for five years, also when the machine’s PC is replaced.
5. Withstanding attacks
The regulation. Section 1.2.1 (a): the control system withstands reasonably foreseeable malicious attempts by third parties that lead to a hazardous situation.
Do it yourself. netbox-ot records the target and achieved security level per zone and per conduit according to IEC 62443, with a risk assessment per zone or conduit. From the allowed connections it builds a list of firewall rules as CSV, which you can check against the machine’s router.
Packetflow. Reviews the design: zones, firewall rules and what is open towards the customer’s network.
6. When the network connection drops
The regulation. Section 1.2.6: an interruption, the re-establishment after an interruption or a fluctuation of the network connection must not lead to a hazardous situation.
Do it yourself. Put network interruptions in your tests before delivery: pull a cable, restart the switch, drop the link to SCADA or to the vendor, and watch what the machine does when everything comes back. The results belong with the test reports in the file.
Packetflow. Prepares those tests with you and runs the network side of them, together with your engineer.
7. Every machine in the series the same
The regulation. Annex IV asks, for machines produced in series, the internal measures that keep each machine in conformity.
Do it yourself. Keep the reference machine in NetBox as the model and give each delivered machine a tag with its serial number.
Packetflow. Works out a reference design per machine type: the network, the router and remote access, so every machine of that type starts the same way.
8. The instructions
The regulation. Section 1.7.4.2: the instructions contain the drawings and diagrams for use, maintenance and repair, and the installation and connection instructions. Digital instructions stay available online for the expected lifetime of the machine and at least ten years.
Do it yourself. Print the netbox-ot machine drawing to PDF and add it to the chapter on connecting the machine. The header names the machine, the version you enter and the date. The device, cable and outside-connection lists go along as CSV.
Packetflow. Writes the chapter on the connection, remote access and the software, in plain language.
Starting yourself in NetBox
netbox-ot and netbox-access-paths need NetBox 4.7 or 4.8 and Python 3.12. Version 5.0.2 of netbox-topology-views goes with NetBox 4.7; for other versions, the table in its README lists the right one. On a standard installation under /opt/netbox:
source /opt/netbox/venv/bin/activate
pip install netbox-topology-views==5.0.2 netbox-ot netbox-access-paths
printf '%s\n' netbox-topology-views==5.0.2 netbox-ot netbox-access-paths >> /opt/netbox/local_requirements.txt
In configuration.py:
PLUGINS = ["netbox_topology_views", "netbox_ot", "netbox_access_paths"]
PLUGINS_CONFIG = {
"netbox_topology_views": {"allow_coordinates_saving": True},
}
cd /opt/netbox/netbox
python3 manage.py migrate
python3 manage.py collectstatic --no-input
sudo systemctl restart netbox netbox-rq
Then, per machine type:
- Device types. For switches and routers there is the NetBox community’s devicetype-library. For PROFINET devices, ot-devicetypes builds them from the GSDML files.
- Devices, interfaces and addresses of the reference machine, with the firmware version in the netbox-ot field.
- Cables between the interfaces. The drawing comes from those cables: a device without a cable floats on its own.
- The drawing. Under OT > Reports > Machine drawing, pick the machine’s tag or location, enter the version and click Draw. Print to PDF (A3 landscape) or download the SVG. A location shows the same drawing as a tab.
- Zones and connections in netbox-ot, and the access paths in netbox-access-paths.
Export again after every change to the machine, and keep the exports in the file with the date and the machine’s version.
What Packetflow does not do
Packetflow does not certify and is not a notified body. The risk assessment of the machine, the safety functions, the safety software and the conformity procedure stay with you as the manufacturer, as does the machine program. This article is not legal advice.
Sources
- EUR-Lex: Regulation (EU) 2023/1230 (Annex III, sections 1.1.9, 1.2.1, 1.2.6 and 1.7.4.2; Annex IV, Part A; Article 54)
- EUR-Lex: Corrigendum of the date of application (14 January becomes 20 January 2027)
- Eurogip: Machinery Regulation 2023/1230: what the Digital Omnibus on AI changes (Regulation (EU) 2026/1744)
- CEMA and other industry federations: Joint industry call on cybersecurity and the Machinery Regulation (January 2026)
- GitHub: netbox-topology-views (compatibility table, export to PNG and draw.io)
Packetflow reviews your work or works out one machine type with you. Say through contact which machines you ship and how your engineers get in today.